CSA with General Electric for main machines, maintenance schedules as per O&M manuals in terms of scope and periodicity. All as built drawings, performance data and manuals are available.
HEAT RECOVERY STEAM GENERATORHEAT RECOVERY STEAM GENERATOR
Manufacturer: NEM, Type: horizontal, Pressure in stages (bar) HP:58;LP:5, Gas Temperature Entry (ºC) 598, Gas Temperature Exit (ºC) 102, Production of steam: (t/h) 65
STEAM TURBINE GENERATORSTEAM TURBINE GENERATOR
Manufacturer: VATEC-ELIN, Type: OLES 3Phase WYE CONN 50 Hz, Output: (MVAR) 40, Voltage: (kV) 11,5, Power factor: (cos Æ) 0,8
STEAM TURBINESTEAM TURBINE
Manufacturer: GE, Type: Vacumend, Production: (Mwe) 40,8, Entry Pressure: (bar)56, Outlet Temperature: (C) 48, Turbine Speed: (rpm) 3000
GAS TURBINE GENERATORGAS TURBINE GENERATOR
Manufacturer: VATEC-ELIN, Type: 2Poles 3Phase WYE CONN 50 Hz, Output: (MVAR) 39, Voltage: (kV) 11,5, Power factor: (cos Æ) 0,8
GAS TURBINE 5GAS TURBINE 5
Manufacturer: General Electric, Type: Frame 6C, Production: (Mwe) 2 x 42,3, Pressure ratio:1/16,4, Flow rate: (Ib./sec) 110, Turbine speed: (rpm) 7100, Exhaust gas temperature:(ºC) 600, Specific consumption: (Sm3/Mwh) 310
REFERENCE CONDITIONREFERENCE CONDITION
Air intake temperature: (ºC) 18, Relative humidity: (%) 55, Baromatic pressure: (mBar)990, Fuel: Natural, Gas Backup fuel: Distillate oil
SUMMARY INTEGRATED PLANT (DESIGN SPECIFICATION)SUMMARY INTEGRATED PLANT (DESIGN SPECIFICATION)
Net electrical power: (MW) 125,4, Net electrical effi ciency: (%) 51, Ambient temperature: (ºC) 18, Air pressure: (mbar) 990
HEAT RECOVERY STEAM GENERATORHEAT RECOVERY STEAM GENERATOR
Manufacturer: NEM, Type: horizontal, Pressure in stages (bar) HP:58;LP:5, Gas Temperature Entry (ºC) 598,Gas Temperature Exit (ºC) 102, Production of steam: (t/h) 65
STEAM TURBINESTEAM TURBINE
STEAM TURBINE The steam turbine is a GE Vacumend with combined HP/LP. Steam from the heat recovery steam generator (HRSG) drives the single steam turbine, which has a power output of up to 40,8 megawatts of